Aller au contenu principal
Article language
STOLL/SleepBase/Climate and materials

Climate and materials

Air circulation in the mattress core

System design more important than material label

Your gateway to sleep knowledge

Welcome to SleepBase.

Use your STOLL access to explore in-depth research on better sleep.

No access yet? Speak to your STOLL advisor.

Explore and understand

Discover connections.

Choose an approach, then explore each step with your mouse, keyboard or touch.

Box spring

Potential contribution

Large cavities in the spring area

Qualitative interpretation. These connections do not establish causality; no product measurements are simulated.

Change perspective

What does this mean in practice?

Open core

An open core creates potential flow paths.

Putting it in context

Without air supply and exhaust, a large part of the air remains in the bed.

The research question

Understanding the findings.

Box springs, polyurethane foam, Dunlop latex, and Talalay latex differ in their construction. However, this does not result in a universally valid ranking of nocturnal cooling. The decisive factor is whether heat and water vapour can reach the ambient air from the point of loaded body contact. A ventilated core beneath a highly restrictive topper can be less effective in the finished bed than a carefully coordinated foam system. This analysis separates air permeability, thermal conduction, moisture retention, and actual air exchange. For STOLL, this results in a clear testing strategy: investigate complete set-ups under comparable load and only communicate design advantages to the extent supported by measurements.

Physical fundamentals of the bed climate

Heat leaves the body through conduction, convection, radiation, and evaporation. In close contact with the mattress, convection differs from that on skin exposed to free airflow: body weight compresses padding and closes part of the flow paths. Air in the core is therefore not automatically moving air. For an air stream to be created, connected pores or channels as well as a driving pressure difference are required. Movement can displace air; however, a true exchange with the room only occurs via open inflow and outflow paths. Air permeability is described as volume flow relative to area and test conditions. Water vapour transmission can also occur without significant air flow. The sorption of a fibre, in turn, means that moisture is temporarily stored. An absorbent surface may initially feel drier, even though it must later release the moisture again. In product advice, these variables must not all be summarised as "breathability". ISO 9237 describes an air permeability test for textiles; this is not a test of the nocturnal cooling performance of a complete bed. [1]

Box spring as a multi-layered air path

A spring core contains large cavities between mechanically supporting elements. This fundamentally creates space for air movement. Whether this space is connected to the bedroom, however, depends on side covering, base closure, base box, and top layers. Pockets around individual springs, adhesive areas, felt layers, and foam edges change the possible paths. Furthermore, the term box spring refers to a system design and not a uniform material sample. In a typical comparison, at least the base box, mattress, topper, protective layer, and fitted sheet must be documented. If a box spring with a thin comfort layer is tested against a thick foam core with a waterproof cover, the differences found cannot be attributed solely to the springs. A meaningful development trial therefore first varies the core with a constant surface and then the entire ready-for-sale assembly. Both questions are relevant, but answer different things.

Foam and the significance of open structures

With flexible foams, cell size, cell connections, remaining cell membranes, bulk density, and compression determine flow resistance. The terms cold foam and visco-foam do not sufficiently define these characteristics. Additionally, contour cuts, drill holes, vertical channels, and laminated layers influence transport. A superficial ventilation cut can collapse under load; an open channel must end at an effective outlet to allow exchange. A cool initial touch describes primarily the initial heat flow. It does not prove permanent heat dissipation after several hours. Likewise, a heat-storing additive can temporarily buffer a temperature rise without permanently removing heat from the bed. For interpretation, temperature profiles are therefore more meaningful than a single measurement point immediately after lying down. Testing heat and water vapour transmission on patient surfaces already methodologically shows why the surface must be investigated as a total thermal system. [2]

Dunlop and Talalay in a fair comparison

Dunlop and Talalay are manufacturing processes for latex foam. The process control can produce differences in density distribution and cell structure. A plausible working hypothesis regarding air paths can be derived from this, but not a robust universal factor such as "three times more breathable". Such a factor requires two clearly named products, the same test method, the same sample geometry, and the same load. For consultation, natural latex content, total density, firmness, perforation, thickness, and cover must also be distinguished. Comparing a soft Talalay comfort layer against a firm Dunlop core mixes process and function. Even air passage facilitated by perforation says little about moisture release through the sheet above it. In the literature reviewed here, no independent study was identified that sufficiently compares all four ready-for-sale system types under identical nocturnal conditions. The appropriate conclusion is an open product comparison, not a winner's claim.

Load, moisture, and temporal progress

A dry, unloaded laboratory test only maps a portion of usage. The shoulders and pelvis compress the construction differently; side and back positions change the contact surface and enclosed air volumes. A partner can introduce additional heat and moisture into the same bed. The difference between room and bed temperature also influences transport. Material evaluations therefore require a fixed environment and a time-defined loading sequence. A clear model treats the individual layers as transport resistances connected in series. If a dominant resistance increases, improving an already well-permeable core brings little benefit. The model explains a potential bottleneck but does not replace measurement because lateral paths, compression, and moisture retention are not fully captured. On the interactive side, design scenarios are therefore explained without outputting fabricated flow values as material data.

Pore size, convection, and conduction

Pore size alone does not determine air exchange. Connected open pores, cell membranes, tortuosity, and compression influence resistance. A large closed cavity can store air without exchanging it. According to a simplified Darcy approach, volume flow increases with pressure difference and permeability and decreases with path length. This relationship is a model description for suitable flow conditions, not a direct characteristic curve of a latex product. For Dunlop and Talalay, permeability and load state must be measured on the specific material. Conduction transfers heat in contact; convection transports energy with moving air. Under a loaded contact zone, conduction may dominate, while lateral free areas react differently. The sum of thermal resistances explains potential bottlenecks but maps motion-dependent air paths only incompletely. A test plan therefore varies perforation, compression, and edge opening separately and measures heat flow alongside air passage. A larger hole diameter does not result in a guaranteed cooler night.

Transport resistances as a technical mental model

For a simplified vertical transport path, the resistances of the cover, comfort layer, and core can be thought of as additive. If the cover already accounts for the largest share, the improvement of another element has a relatively small effect on the overall result. Conversely, a more permeable surface can make an existing core effectively usable. This model explains why the assessment of an individual material often leads to overly optimistic product promises.

In reality, additional lateral paths exist. Moisture can be stored and later released; contact surfaces change during movement. Therefore, a purely stationary calculation is only a structural aid. For development, it should be used to select the most likely important test variants. It must not be used to generate a material ranking without measurement. Particularly important is the difference between an improvement in the transport path and a measurable change in sleep. Even a significant laboratory difference can remain small under actual conditions of use if, for example, the duvet dominates the sensation of warmth.

Hypothetical case of a latex bed perceived as warm

Assume a person sleeps on a perforated latex core and reports sweating at night. On top of this are a thick topper, a protective pad, and a heavy duvet. The first hypothesis should not automatically be that the latex manufacturing process is unsuitable. Multiple resistances present at the same time and the overall insulation can explain the problem.

A sensible individual comparison first changes a safe, dispensable comfort component while maintaining necessary protection. The person documents the sensation of warmth, moisture, and room temperature over several nights. If it becomes more comfortable, this is an indication of the suitability of the modified configuration. It still does not prove that latex is generally warm or another material is generally cool. For STOLL, this distinction is particularly useful: the solution can start with the existing bed and does not need to be justified by an unsubstantiated material diagnosis.

Which manufacturer documents really help

A usable report states the sample construction, dimensions, load, pre-treatment, and measurement environment. If only core samples are tested, this must be clear. Comparative products should be as similar as possible in terms of thickness and mechanical function, or their differences must be expressly stated.

Statements regarding nightly cooling require a temporal progression. A single infrared image shows surface temperature under certain conditions, not the entire heat transport. Also, an air flow through an unloaded sample is only a partial finding. STOLL should therefore require separate evidence for the material, the assembled system, and usage. Where data is missing, a design property can be described without turning it into a verified effect on sleep.

Benefits and limitations

Approaches in comparison.

ApproachPotential contributionLimits of the evidence
Box springLarge cavities in the spring areaTopper, side finish, and base box can limit exchange
Foam systemOpen cells and channels can enable transportPore connectivity and compression are product-specific
Dunlop latexElastic porous core with possible perforationNo uniform air permeability of the process
Talalay latexDifferent cell structure possible depending on the processNo blanket cooling advantage without comparative testing

What can be measured.

MetricTestImportant limitation
Air permeabilityDefined pressure and sample conditionTests flow path, not sleep quality
Temperature profileContact surface over several hoursSeparate initial cooling from long-term effect
Relative humidity and temperatureSimultaneous measurement at multiple pointsRelative humidity alone is temperature-dependent
DryingMass before and after defined humidificationDistinguish storage from release

From research to application

Guidance for practice.

A reliable test plan

A two-stage STOLL trial should first place identical top layers on different cores. Afterwards, the four complete retail set-ups are tested. All samples receive the same climatic pre-treatment. A heated, loaded test specimen with a defined moisture supply is preferable to an uncontrolled manual test. The positions of the sensors, load distribution, room climate, measurement duration, and movement rhythm must be established in advance. Several specimens per model help avoid confusing the peculiarity of individual samples with a material effect. A subsequent sleep study requires alternating sequences, habituation, and separate data on thermal comfort and measured sleep. This procedure is a proprietary test design, not a cited standard requirement.

Implications for customer advice

During consultation, first clarify whether the problem is heat, moisture, or both. Then record the entire existing assembly including the protective layer. Changing a dominant top layer can be more sensible as a manageable test than immediately replacing the core. Manufacturers should provide comparative values with test conditions and loaded assemblies. Statements such as "open spring space" are structurally comprehensible; "guaranteed less sweating," however, requires usage data. For a latex comparison, two concrete models with similar firmness and thickness should be available. The result is explained as an individual fit with documented limitations.

Evidence and practical implementation

For classification, the primary criterion is whether the source examines the exact question asked. A technically precise material measurement can be highly informative for a material property while saying little about sleep or long-term health. A clinical study may show a relevant benefit, but only for the group of people, construction, and duration of use studied. Proximity to the concrete question is therefore just as important as the study design.

Subsequently, comparison conditions, sample size, observation duration, and potential biases are considered. Blinding is often difficult with bedding. Expectations, habituation, and the sequence of tested variants can influence results. In the case of manufacturer funding, transparency and independent replication are particularly helpful; funding alone does not decide for or against the validity of a finding. Small pilot studies are primarily used to formulate a question more precisely and to plan a larger trial.

Statistical significance is not the same as practical importance. A small difference can be mathematically detectable without having a tangible benefit for the person in question. Conversely, a relevant individual improvement may remain statistically uncertain in a small group. Therefore, effect size, uncertainty, and everyday relevant endpoints are assessed together. A blanket score would obscure these differences. The interactive companion page consequently does not use fabricated health scores or simulated figures that appear like measured material data.

For implementation, a concrete goal is first defined, and then the smallest reasonably testable change is selected. The initial state, construction used, and observation period are documented. Feedback should capture both the desired benefit and possible new disadvantages. If several components are changed simultaneously, the attribution of success remains uncertain. An individual comparison can improve personal selection but does not replace a general efficacy study.

A supplier proof should concern the model actually offered and the intended use. Deviations in the cover, topper, base, care, or software can alter the transferability. The consultation openly states such limitations and formulates only the performance covered by data or immediate observation. For medical or legal questions, the relevant professional assessment remains necessary. The practical recommendation of this document is a basis for decision-making and not an individual diagnosis.

Research you can trace

Sources and context.

Research methods and limitations

This paper is a targeted narrative research as of 30 September 2026. The starting point is the specific topic question, scientific publications, and, for technical or legal questions, the relevant original sources. The Word documents provided by the client serve as templates for the professional structure and comparative presentation. Their individual statements have not been adopted without verification. This research is not a systematic comprehensive survey, a meta-analysis, or a product certification.

The sources were checked via accessible publication sites, bibliographic datasets, and available excerpts. A complete article was not accessible for every source. Where only an abstract or excerpt was available, the description is limited to the information discernible therein. Figures are only mentioned within their study context; missing details are not supplemented. A phrase such as "no reliable evidence identified" describes the result of this targeted research and does not prove that no such work exists worldwide.

The source numbers in the text refer to the list at the end. Directly examined findings, mechanistic considerations, and the author's own practical deductions are linguistically separated. Hypothetical cases illustrate the decision-making logic; they are not documented customer experiences. The suggested test plans are original designs. They do not establish a binding standard or a medical treatment process. Statements about a product class are not automatically transferred to individual models.

English translation of the German original. Bibliographic references and Word files remain in their original language.

SleepBase by STOLL · Research status: 30 September 2026
Scientific interpretation with sources and limitations. Not an individual medical diagnosis.